Hello dear members of the group
Regarding the said incident, I express my opinion in several points
1- According to article 0-3-6 of the standard of electric elevators to 1-6303, version 1393, users must be protected against the risks that occur when using the elevator due to their own inadvertent carelessness and mistakes.
In my opinion, based on the above, no responsibility can be assigned to the deceased and his colleagues.
2- According to article 0-3-3 of the standard of electric elevators number 1-6303, 1393 version, parts must be selected and installed in such a way that predictable environmental effects and special working conditions do not interfere with the safe operation of the elevator.
3- The cabin has experienced unwanted movement (subject of Article 0-3-3 of the standard of electric elevators No. 1-6303, 1393 version), the cabin should not move before the floor door is completely closed and locked (subject of Article 1-3 7-7 of the standard of electric elevators No. 1-6303 version 1393) that here the cabin has moved before the door is fully locked and this is non-compliance with the technical requirements and as long as the locking components are involved, at least 7 mm the cabin should not be able to move (Article 1-3-7-7 of the standard of electric elevators number 1-6303 version 1393) and to stabilize and ensure the above-mentioned conditions, each floor door should be equipped with an electric safety device ( be in accordance with paragraph 2-1-14) (the subject of article 1-4-7-7 of the standard of electric elevators, number 1-6303, version 2013)
4- According to article 1-3-3-16 of the standard of electric elevators, number 1-6303, 1393 version, in order for the elevator to be in good condition during operation, periodic inspections must be carried out. These periodical inspections and tests must be done according to Appendix (C), in accordance with Article 15-2-6-3 of the 15th topic of the National Building Regulations 2012 version, the maintenance contract is always mandatory, and in the absence of a contract with competent persons Dar (which apparently there was no competent person in the matter of this incident) and the conclusion of a proper maintenance contract should exist, and in this regard, in my opinion, due to the weakness of government institutions and organizations, proper contracts have not been issued in the country, and there are many weaknesses in It can be seen that the origin of most of them is economic, in other words, the users are not willing to pay a fair and appropriate fee to the service and maintenance, there is no need to enter into this discussion.
However, in accordance with the above requirements, in case of not concluding a suitable contract with competent natural and legal persons and an accident occurs, the responsibility lies with the employer or the building contractor (the subject of Article 1-3-3-16 of the standard of electric elevators, No. 1-6303, 1393 edition). )
In addition, in the inspection and maintenance of the elevator, while complying with Appendix (C) in the electric elevator standard numbered 1393-1-6303, the requirements listed in section 22-10 of the twenty-second topic of the National Building Regulations under the title of care and maintenance of the building should also be considered. and be observed.
The fact that the operators of the building, due to economic considerations and lack of knowledge of the important issue of service and maintenance, leave it to unqualified persons, and in addition, according to the text of the current contracts in the country, their conditions are inappropriate, the result will not be part of the occurrence of such damages. .
Other cases such as bridging of the doors, absence of the self-closing spring behind the door and other technical reasons for the accident will require careful visits and controls.
The documented material mentioned in the above text is required and documented in other sources of technical laws related to elevators, such as the bylaws for the construction of workshops approved by the Minister of Labor Cooperation and Social Welfare, the fifteenth topic of the national building regulations under the title of elevators and electric elevators.
Hosseini Elest, Labor Inspector and Official Justice Expert of Qom Province 09391515009